UK MAIB issued a safety bulletin, regarding the investigation of an auxiliary boiler explosion on board the container ship “Manhattan Bridge” to highlight that if signs of waxing in fuel tanks and fuel systems are evident, actions must be taken immediately. A build-up of waxy deposits in boiler burner’s fuel supply filter was one of the likely causes of the flame failure onboard Manhattan Bridge resulting in one fatality and one serious injury in early 2017.
The incident
At about 2304 on 19 January 2017, an auxiliary boiler furnace explosion occurred in the engine room on board the Japan registered container ship Manhattan Bridge as it was berthing alongside a container terminal in Felixstowe, England. Manhattan Bridge’s second engineer and an engine room oiler were investigating a boiler fame failure alarm at the time and were caught by the blast. The oiler suffered severe injuries and died soon after the explosion. The second engineer suffered burn injuries to his face and right arm, which required a skin graft.
The boiler had tripped out several times due to flame and ignition failures earlier in the day and had been successfully restarted by the second engineer.
Following the accident, waxy deposits, sufficient to cause intermittent fuel supply problems, were found in the boiler’s distillate fuel supply filter.
Fuel samples tested against the latest international marine fuel quality standard identified that wax crystals large enough to block the filters could start to form in the fuel at a temperature of 14°C or below. The air and sea temperature at the time of the accident at Felixstowe was 4°C.
The fuel, which was loaded on board 2 months earlier, had been tested against an older version of the fuel quality standard. The older standard did not include a test to identify cold filter plugging points.
The requirement to comply with increasingly stringent low sulphur emission regulations in sulphur emission control areas (SECAs), such as the North Sea, has increased demand for low sulphur marine gas oils (MGOs). Some low sulphur MGOs have a higher paraffin content and are therefore more susceptible to waxing in cold conditions.
Safety issues Explore more by reading the official document: UK MAIB informed that the Japan Transport Safety Board (JTSB) is conducting an investigation of the accident and will produce a report in due course.
How could the explosion take place if there was a flame failure. No flame no explosion.
Unless there was some un burnt fuel in the furnace and ignited when they did get a flame. Also the boiler had to purge before the pilot flame ignited the fuel.